Pu Elements PDF
Power Unit Information (v2)
São Paulo Grand Prix · 2026 · 7 November 2026 · Doc 28
Published by the FIA — original on fia.com. This page reproduces the document with its text for search; TracingInsights is not affiliated with the FIA.
2026 SÃO PAULO GRAND PRIX
06 - 08 November 2026
From The FIA Formula 1 Race Director Document 28
To All Teams, All Officials Date 07 November 2026
Time 10:03
Title Power Unit Information V2
Description Power Unit Information V2
Enclosed R20_Brazil_Power_Unit_Information_V02.pdf
Rui Marques
The FIA Formula 1 Race Director
F1 POWER UNIT INFORMATION TO THE TEAMS AND PUMs
2026 SÃO PAULO GRAND PRIX
COMPETITION INFORMATION
| ROUND No. | R20 |
|---|---|
| VENUE | São Paulo |
| CENTRELINE | 4.309 km |
| FORMAT | Standard |
| DATE | 06-08 November |
POWER AND ENERGY LIMITS
| Article C5.2.10 Maximum Recharge per lap | Article C5.12.8 Maximum PU Power Reduction Rate | |||||
|---|---|---|---|---|---|---|
| Race | Qualifying | Free Practice sessions | Out laps other than in Race | Power Limited Distance | Rate Limit | |
| Overtake not active | Overtake active | |||||
| 8.0 MJ | 8.5 MJ | 6.5 MJ | 8.5 MJ | 9.0 MJ | 2278 m | 100 kW/s |
| Article C5.2.8 Maximum DC power of ERS-K function of car speed | 350 Wk( 300 re | |||||
|---|---|---|---|---|---|---|
| Sprint & Race | Any Practice Session incl. Qualifying Sessions | |||||
| Main Overtaking Zones Other parts of the Lap Overtake not active Overtake active | Base - S Base - O | tandard vertake | ||||
| Overtake not active | Overtake active | Alt 1 | ||||
| Base - Standard | Base - Overtake | Alt 1 | Base - Overtake |
IDENTIFICATION OF SECTORS WHERE EXCEPTIONS APPLY
| Article C5.2.8iii Sectors where the alternative power curve defined above applies in Sprint & Race | Article C5.12.4 Sectors where the PU power reduction at the start of a Power Limited Pending period can be greater than 150kW (sectors indicated by [ ] are for SQ and Q only) | Article C5.12.5 Sectors where a reset of MGUK power reduction is permitted (sectors indicated by [ ] are for SQ and Q only) | ||||
|---|---|---|---|---|---|---|
| Identification of Sectors | Lap distance window [m] | Identification of Sectors | Lap distance window [m] | Maximum PU power reduction permitted | Identification of Sectors | Lap distance window [m] |
| T6-T12 | 2000-3150 | T6-T10 T11-T12 [Exit T12] | 2000-2700 2900-3150 [3200-4300] | 350kW 350kW [350kW] | Exit T11 [Exit T14] | 2900-3050 [3700-4300] |
| Article C5.12.7 | ||
|---|---|---|
| Sectors with a higher speed threshold | ||
| Identification of Sectors | Lap distance window [m] | Speed threshold |
| T11 | 2870-2970 | 240km/h |
| OVERTAKE | ||
|---|---|---|
| Article B7.2 | ||
| Detection Gap | Detection Line [sLap & Loop] (Art. B7.2.1b.viii) | Activation Line [sLap & Loop] (Art. B7.2.1b.ix) |
| 1.0 s | 3250 m L17 | 3411 m L18 |
Loading F1 AI…